The Bioenno Lithium Iron Phosphate batteries included with the A and B series go kits operate over the temperature range of -10 to +40C (14 to 104F).

The batteries can be charged over the range 0 to 37C (32 to 99F).  Charging below 0C will damage the cells.

Instructions for Use Charging 

1. Only use 14.6V, LiFePO4 compatible chargers to charge the battery. The charging current should be between 2A to 5A. If you need a charger, please contact us. 

2. Fully charge the battery before first use. This depends on the output of the charger but is typically between 3-8 hours. 

3. If your battery came with a Bioenno Power charger, please note that the LED light on the battery does NOT indicate the state of charge. A red LED light means the battery is under constant current (CC) charging and green LED means constant voltage (CV) charging. Always charge for at least 8 hours to ensure full capacity. 

4. LiFePO4 does not suffer “memory effect” so please keep the battery fully charged for daily use. Cell balancing only occurs when the battery is fully charged (top-end balancing).

5. Do not charge the battery in temperatures below 0°C. This can cause damage to the cells.   

User Manual